User's Manual Part 1
2.4GZ OpenWay Remote Mount Gas Module Installation
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount 6
Proprietary and Confidential
Meter
Model
Description
Class
Comments
Endpoint Type
ERT Part
Number
Mercury Correctors
EC-AT
Mini-P
Mini-AT
Mini-Max
Pressure and
temperature electronic
volume correctors
Commercial
IPP*
SEP*
Correctors must have a Form
A board; Form C is NOT
supported. Item #056 Pulse
Scaling Factor must be set to
2.0. Item #096 Cor Vol
Display must be set at 1, 2, 3,
or 4 blanks. Endpoint does
NOT support 8 digits (0
blanks). Item #1014 set to the
preset "Itron" selection in the
drop-down menu. Item #115
Output Pulse Code must be
set at 1, 2, 3, or 4 (not "0").
2.4GZ OpenWay Remote
5'cable
2.4GZ OpenWay Remote
5'cable
OWG-5001-502
OWG-5002-502
Mercury Correctors
TCI
Temperature
Compensating index
Commercial
IPP*
SEP*
Correctors must have a Form
A board, Form C is NOT
supported. Item #56 Pulse
Scaling Factor must be 2.0.
Item #96 must be 7, 6, 5, or 4
digits (1, 2, 3, & 4 blanks).
Endpoint does NOT support 8
digits (0 blanks). Item # 1014
set to the preset “Itron”
selection in the drop down
menu. Compatible firmware
versions on TCI are 1.06,
1.07, and 1.10.
2.4GZ OpenWay SE 1.0
Remote with 12" lead wires
2.4GZ OpenWay SE 1.0
Remote with 12" lead wires
OWG-5001-504
OWG-5002-504
*IPP: Itron Private Profile