User's Manual

Installing the 2.4 GHz OpenWay Gas Module on a Sensus Mete
r
2.4GZ OpenWay Gas Module Installation Guide 25
Once properly in place, the index drive gear and backplate wriggler cup should look
similar to the following example.
4. Attach the right-hand mounting screw to the index and meter, just far enough to hold
the index in place. Use one 6 - 32 x 5/8-inch screw for this step (you can use an
original mounting screw if it was the correct size and not corroded; otherwise, use the
correct size Replacement Screw see "Replacement Screws" on page 21).
2
1
5. Install and tighten the left-hand index mounting screw.
6. Tighten the right-hand index mounting screw completely.