User's Manual

Initializing, Connecting, and Programming the ERT Module
TDC
-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 11
Proprietary and Confidential
Programming the 100WP/100WP+ ERT Module
Programming the 100WP/100WP+ requires one of the following handheld computers running Field
Deployment Manager (FDM) version 3.2 or later.
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
For normal activation, connect the 100WP/100WP+ to the water meter register and program the ERT module
with FDM.
100WP/100WP+ Pulser ERT Module Start-up
The 100WP/100WP+ enters run mode by completing programming with FDM. Programming sets the
appropriate pulser parameters (initial consumption and utility ID).
Itron strongly recommends performing a Check ERT with a handheld computer running FDM to verify the
100WP/100WP+ is operating correctly after installation. Performing a Check ERT will:
Generate an immediate register read.
Align the 100WP/100WP+'s time with the handheld's time.
Important Periodically dock or cradle the handheld computer or mobile reader to keep the time current.
Verify communication with the Leak Sensor.
Check for tamper flags.
Connecting to a Meter Register Using the Inline Connector
The inline connector system easily allows a separation between the ERT module and meter register and
provides for general maintenance or system troubleshooting (see Using an Inline Connector on page 39).
Connecting to a Meter Register Using a Cable
You may connect the 100W/100W+ and 100WP/100WP+ ERT module to the water meter register using the
5-foot or 20-inch cable.
Caution ERT module wire terminations must be properly sealed with a non-conductive gel
material to prevent water intrusion (otherwise, this configuration should not be used in a pit box
environment). Itron recommends the 5-foot or 20-inch cable configuration for OEM users only.