The following information is provided to help you troubleshoot issues related to the 100W/100W+ and
100WP/100WP+ ERT modules.
The following table describes possible issues and provides suggested actions to resolve the issue.
Issue
Action
Cannot program the ERT module. Check the programming device and software version. Program ERT
modules using the FC300 handheld computer running Field Deployment
Manager (FDM) software.
Cannot read the ERT module. An ERT module that is not programmed will not transmit an
SCM/SCM+. Reprogram the ERT module and perform a reread. If an
ERT module is not initially programmed, it will not bubble-up and listen
for an SCM/SCM+.
The encoder ERT module is reporting an invalid read. An encoder ERT module that has set the Last Good Read flag will cause
an Invalid Read to display in the FDM Consumption field.
Marginal readability due to water ERT module location
(for example, an ERT module deep inside a pit).
Consider reprogramming the ERT module for Hard-to-read (H2R)
mode. This increases the output power to Fixed Network levels.
Note Hard-to-read mode will reduce battery life.
The ERT module in a Fixed Network is not reporting. Perform a Check ERT and verify the ERT module is in FN mode. If the
CCU's pathway is obstructed, consider including an 8-channel repeater.
Systems that utilize Fixed Network v4.0 software and a CCU100 may
require a Repeater 100.
The handheld programmer is locked up and button presses
produce no response.
Soft boot the handheld by pressing and holding buttons A and B until the
screen fades. Release the buttons and allow the handheld to reboot.