This section describes the procedure for installing Itron cable armor in a field installation. The Itron armor
cable provides a layer of protection for the module's cable jacket. Itron cable armor is available in 5-foot
sections.
Warning Itron armor cable is stainless steel and may have sharp edges. Use caution when you are
installing the armor cable.
Important If you remove the inline connector from the ERT module to install the armor cable, you
must use an Itron handheld to reprogram the ERT module using FDM Endpoint Tools. Perform a
Check Endpoint function (with in FDM Endpoint Tools) after you reprogram the ERT module to
verify communication with the meter register.
Required Materials
The following materials are required to install the Itron cable armor.
5-foot Itron cable armor
Electrical tape
(Optional) Scissors
To install the Itron cable armor
1. Remove the ERT module from the pit.
Note If it is possible in your field installation, keep the ERT module connected to the register.
2. Cut a two to three inch strip of electrical tape.