User's Manual
Initializing, Connecting, and Programming the ERT Module
TDC-0909-004 100W and 100WP Datalogging ERT Module Installation Guide 11
Proprietary and Confidential
Verifying 100W and 100WP Operation
Use one of the following handheld computers to verify consumption:
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
Notes
Each handheld radio requires special setup and configuration parameters to successfully read
and program 100W and 100WP ERT module products. Refer to the respective meter reading
application for specific instructions.
When comparing the actual register value to that reported by the 100W and 100WP ERT
module, please keep in mind the ERT module's consumption value is updated once an hour
when it is in a Run Mode.
Caution Do not use ReadOne Pro, FS2PN, FS3PN, or FC200R readers to read the 100W and
100WP ERT module. These readers do not operate their receivers long enough or at the right
frequency to reliably capture a 100W and 100WP ERT module transmission.