User's Manual
Initializing, Connecting, and Programming the ERT Module
TDC-0909-004 100W and 100WP Datalogging ERT Module Installation Guide 8
Proprietary and Confidential
Programming the 100WP
Programming the 100WP requires one of the following handheld computers running Field Deployment
Manager (FDM) version 1.0 or later.
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
For normal activation, connect the 100WP to the water meter register and program the ERT module with
FDM.
100WP Pulser Start-up
The 100WP enters Run mode by completing programming with FDM. Programming sets the appropriate
pulser parameters (initial consumption and Utility ID).
Itron strongly recommends performing a Check ERT with a handheld computer running FDM to verify the
100WP is operating correctly after installation. Performing a Check ERT will:
Generate an immediate register read.
Align the 100WP's time with the handheld's time.
Important Periodically dock or cradle the handheld computer or mobile reader to keep the time current.
Verify communication with the Leak Sensor.
Check for tamper flags.
Connecting to a Meter Register Using the Inline Connector
The inline connector system easily allows a separation between the ERT module and meter register and
provides for general maintenance or system troubleshooting (see Using an Inline Connector on page 39).
Connecting to a Meter Register Using a Cable
You may connect the 100W and 100WP ERT module to the water meter register using the 5-foot or 20-inch
flying leads cable.
Caution ERT module wire terminations must be properly sealed with a non-conductive gel
material to prevent water intrusion (otherwise, this configuration should not be used in a pit box
environment). Itron recommends the 5-foot or 20-inch cable configuration for OEM users only.