This section describes the 100W connections to the water meter register using the inline connector assembly.
Follow the manufacturer's recommended procedure for installing the water meter register on the meter.
To connect the inline connector
Note If an inline connector is not used and the ERT module is already connected to the water meter
register, skip this step.
1. Remove the protective cover from the connector by twisting the two halves in opposite directions. Pull the
halves apart.
Caution Verify the connector halves are clean and dry before assembly.
If any of the following conditions occur, do not install the ERT modules:
• Any of the three pins are damaged or missing.
• The O-ring is missing.
• The cable is cut or nicked.
2. Connect the register cable to the ERT module connector. Holding the connectors by the back shells, rotate
one end to align the keyed slots. Push until snug. Slide the black coupling nut over the O-ring. Make sure
the O-ring stays seated. If the O-ring does not stay seated, disconnect and try again.
A
PPENDIX
A
Using an Inline Connector