Installing the 100W and 100WP ERT Module
TDC-0909-003 100W and 100WP Datalogging ERT Module Installation Guide 27
Proprietary and Confidential
Leak Sensor Mounting 100W/100WP ERT Optional mounting bracket
bracket
Warning When the 100W or 100WP is installed but the Leak Sensor is not attached, you must
protect the blue Leak Sensor port with the environmental cap (MSC-0019-005). If you remove the
Leak Sensor from the ERT module, the environmental cap must be replaced to protect the
connector.
To connect the Leak Sensor to the 100W and 100WP ERT module
Caution Verify you have the correct 100W or 100WP ERT module. Leak Sensors must mount to Port B
(top port) of the ERT module. Connecting the LS to Port A (bottom port) will cause electrical damage to
the LS and ERT module.
1. Remove the environmental cap from the ERT module's blue connector (B).
B. Blue connector: Leak Sensor connection
A. Black connector: register connection