User's Guide

Installing the 100W and 100WP ERT Module
TDC-0909-003 100W and 100WP Datalogging ERT Module Installation Guide 17
Proprietary and Confidential
Wall Mount Installation
Select a flat vertical mounting surface. Install the ERT module in an upright position. Locate the ERT module
as high as possible. To mount the ERT module to the wall in a water pit box, select a mounting location on the
inside of the pit box and try to maintain a distance of one to two inches from the bottom of the pit box lid.
Caution Observe the following guidelines for mounting the ERT module using the wall mount
procedure:
ERT module positioning other than upright could negatively affect radio
performance and battery life.
Do not use gel connectors in pit environments.
Use only Itron-approved splice kits or inline connectors.
The ERT module works accurately with Itron-approved cable type and lengths up to 300 feet.
Required Tools and Hardware
Itron 100W Shelf Mount Kit
To install the 100W and 100WP ERT module using the wall mount procedure
1. Select a vertical surface in the pit box or on a wall (for example, an ERT module mounted in a basement).
2. Position the ERT module vertically so the top of the ERT module is between 1 and 2-inches below the
bottom of the lid.
3. Mark the location of the top mounting hole.
4. Drill a pilot hole in the pit box wall. Follow the screw manufacturer's recommendation for the pilot hole
size.