User's Guide

Connecting, Initializing, and Programming the ERT Module
TDC-0909-003 100W and 100WP Datalogging ERT Module Installation Guide 9
Proprietary and Confidential
Connecting the 100WP to a Remote Meter Register
Connect the wires from the ERT module to the register according to the following table.
100WP Connections
Register Manufacturer
100WP wire color
Red
(signal)
Black
(common)
White
(tamper)
Register screw color designator
Elster Digital
BLK GRN R
Itron (Actaris) Cyble Sensor (2-
wire)
Either wire
Remaining wire must be connected to both
ERT module wires
Badger RTR
R BLK Green/bare
Elster V100
BLK R Blue
Sensus PMM
R BLK Bare
Connect the ERT module to the cable using gel-cap connectors (see Using Gel Cap Connectors and the Itron
Splice Kit on page 40).
Using an Extension Cable
Order the 25-foot inline connector extension cable assembly (CFG-0151-401) to extend the 100W with the
inline connector.
Initializing the 100W
Caution To obtain an immediate reading, initialize the 100W with an approved handheld
computer. Failure to initialize the ERT module may delay the initial reading up to one hour.
To initialize the 100W immediately, use one of the following handheld computers running Field
Deployment Manager (FDM) version 1.0 or later.
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
For normal activation, connect the 100W to the water meter register. The ERT module polls for a register
every hour. The 100W automatically activates after the ERT module detects a register.