Connecting, Initializing, and Programming the ERT Module
TDC-0909-003 100W and 100WP Datalogging ERT Module Installation Guide 8
Proprietary and Confidential
To connect the 100W to the register
• Connect the 100W wires to the register screw terminals according to the following table.
Register Manufacturer
100W wire color
Red
(data)
Black
(power/clock)
White
(ground)
Register screw terminal
Elster AMCO Invision
R G B
Elster AMCO Scancoder
R G B
Elster AMCO evoQ4 (Q4000)
R W B
Hersey Translator
G R B
Badger ADE
G R B
Sensus ECR
G R B
Sensus ICE
G R B
Metron Farnier
G R B
Itron (Actaris) Coder
G R B
Neptune ProRead
E-Coder
ARB-V
R B G
Performance ETR
G R B
Severn Trent SM700
SmartMeter
(Sensus Protocol)
G
R
B
Caution Wrap the wire one complete revolution around the register screw. Completely tighten the
register screw and verify the wire insulation is not under the screw terminal heads or intermittent electrical
connection may occur. You must use a moisture-proof sealant if the meter is installed outdoors or in any
environment where moisture can collect on the screw terminals.