User's Manual

About the 100W Endpoint
TDC-0909-002 100W and 100WP Pit Datalogging Water Endpoint Installation Guide 5
Proprietary and Confidential
100W Operating Modes
1. Factory Mode
100Ws ship from the factory in Factory Mode.
The endpoint's transmitter is off.
The endpoint's receiver bubbles-up to listen for a programming command.
100W encoder models attempt to read the register every hour.
Last good read and cut tamper flags may be set when a register is not connected.
If the 100W reads a connected register, the endpoint automatically moves to Run Mode (100W only).
2. Run Mode
100W normal operation mode.
The 100W transmitted message is dependent on its factory settings for standard consumption
messages (SCM) or network interval message (NIM).
For SCM, the 100W default bubble-up rate is 9 seconds.
For NIM, the 100W default bubble-up rate is 6 minutes. When the endpoint is set for NIM, the 100W
transmits a contingency SCM message every minute. Program FN mode with a programming device
to configure NIM mode.
100WP Operating Modes
The 100WP has three standard operating modes.
1. Factory Mode
100WPs ship from the factory in Factory Mode.
The endpoint's transmitter is off.
The endpoint's receiver bubbles-up to listen for a programming command.
100WP encoder models attempt to read the register every hour.
Last good read and cut tamper flags may be set when a register is not connected.
If the 100WP reads a connected register, the endpoint automatically moves to Run Mode and defaults to a
zero consumption.