User's Manual
Connecting, Initializing, and Programming
TDC-0909-002 100W and 100WP Pit Datalogging Water Endpoint Installation Guide 9
Proprietary and Confidential
Connecting the 100WP to a Remote Meter Register
Connect the wires from the endpoint to the register according to the following table.
100WP Connections
Register Manufacturer
100WP wire color
Red
(signal)
Black
(common)
White
(tamper)
Register screw color designator
Elster Digital
BLK
GRN
R
Itron (Actaris) Cyble Sensor (2-wire)
Either wire
Remaining wire must be connected to both endpoint wires
Badger RTR
R
BLK
Green/bare
Elster V100
BLK
R
Blue
Sensus PMM
R
BLK
Bare
Connect the endpoint to the cable using gel-cap connectors (see Using Gel Cap Connectors on page 37).
Using an Extension Cable
Order the 25-foot inline connector extension cable assembly (CFG-0151-401) to extend the 100W with the
inline connector.
Verifying 100W Endpoint Operation
Use one of the following handheld computers to verify consumption:
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
Notes
Each handheld radio requires special setup and configuration parameters to successfully read
and program 100W products. Refer to the respective meter reading application for specific
instructions.
When comparing the actual register value to that reported by the 100W endpoint, please keep
in mind the endpoint's consumption value is updated once an hour when it is in a Run Mode.
Caution Do not use ReadOne Pro, FS2PN, FS3PN, or FC200 readers to read the 100W
endpoint. These readers do not operate their receivers long enough or at the right frequency to
reliably capture a 100W endpoint transmission.