User's Manual

About the 100W Endpoint
TDC-0909-002 100W and 100WP Pit Datalogging Water Endpoint Installation Guide 6
Proprietary and Confidential
2. Run Mode
100WPs normal operation mode.
The 100W transmitted message is dependent on its factory settings for standard consumption messages
(SCM) or network interval message (NIM).
For SCM, the 100WP default bubble-up rate is 9 seconds.
For NIM, the 100WP default bubble-up rate is 6 minutes. When the endpoint is set for NIM, the 100WP
transmits a contingency SCM message every minute. NIM mode is configured by programming NIM
mode with a programming device.
3. Quiet Mode
OEMs can configure the endpoint for quiet mode after programming and direct mounting the 100WP-R in
a factory.
An endpoint is awakened from quiet mode and enters Run Mode in one of two ways:
Counting two pulses. The pulses are counted internal to the 100WP-R while it is in quiet mode.
Receiving a two-way command, such as a Read ERT using FDM.
If an endpoint installed in quiet mode is not bubbling up SCM or NIM messages, it may be due to zero
consumption on the endpoint, such as a vacant or vacation home. Initiate a two-way command (for
example, perform a Read ERT with FDM) before removing the unit.