User's Manual

Installing the 100W-R and 100WP-R Endpoints
TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 25
Proprietary and Confidential
6. Insert a tamper seal over each mounting screw and drive into place with a nut driver or a similar tool.
Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16 inch below the
top of the screw recess.
7. Secure any excess cable using the provided cable ties.
Direct-Mounting to the Meter Register
Direct mounting endpoints to a meter register requires a register designed for that purpose. This section
describes 100W-R and 100WP-R installation for the following direct mount registers:
Badger ADE and RTR
Elster/AMCO (ABB) Scancoder, InVISION, and Digital
Note If you are installing an endpoint with Leak Sensor capability, use a needle-nose pliers to remove one of
the endpoint's housing knock-outs to accommodate the Leak Sensor cable. If your meter register has a raised
internal rim, remove the larger case knock-out.
Warning Do not use the direct mounting method in a pit environment. Use a pit endpoint for pit
environments. 100W-R and 100WP-R endpoints direct mounted in a pit environment are not
covered by the Itron warranty.