User's Manual

Installing the 100W-R and 100WP-R Endpoints
TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 20
Proprietary and Confidential
Pipe Preparation
Clean any dust or dirt from the pipe to facilitate direct contact with the LS surface.
Required Equipment
Equipment
Itron Part Number
Leak Detection Sensor
LDS-0001-001
Optional mounting bracket
CFG-0349-002
100W-R Encoder Remote
ERW-1300-114
100W-R Pulser Remote
ERW-1300-116
Leak Sensor Standard mounting 100W remote endpoint Optional mounting
bracket bracket
To install the Leak Sensor on a pipe or meter insetter
1. Select a Leak Sensor mounting location. Mount the sensor on the water input side of the meter.
Caution The Leak Sensor must be mounted on the water input side of the meter. Failure to follow this
mounting requirement could result in errors in the leak detection data. Installation requires Itron mounting
hardware. Repair costs and service charges relating to the use on non-compliant mounting hardware will
be charged to the customer. Contract Itron Support for more information.
2. Verify the pipe’s mounting surface is free from dirt and debris. Place the curved surface of the LS against
the pipe.