User's Manual

Installing the 100W-R and 100WP-R Endpoints
TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 32
Proprietary and Confidential
5. Install four Torx-head mounting screws (Itron Part Number SCR-0010-005) as shown below. Hand
tighten each screw.
6. Connect the endpoint wires to the register screw terminals following the 100WP-R pulser to the
Elster/AMCO meter register wire connections, (see Connecting 100WP-R to a Remote Meter Register on
page 8). After connecting the wires, carefully tuck the connectors into the endpoint housing. Tighten all
screws securely.
Caution Install the wires around the screws in a clockwise direction (as shown) or the wires may come
out from under the screw heads as you tighten them. Also, verify insulation is NOT compressed under the
screw head, or the wire may not make good contact.
7. Install the module and mounting bracket on the meter register adapter collar.
8. Replace the hollow pin (1) you removed in step 1.