User's Manual

Installing the 100W-R and 100WP-R Endpoints
TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 26
Proprietary and Confidential
To install the 100W-R and 100WP-R endpoints to a Badger Direct-Mount register
Caution
Verify you have a Badger meter with a register designed for direct mount endpoints.
Check the part number on the label to verify the module matches the meter.
Always install the module with the arrow on the housing pointing upward.
Note The register may or may not be mounted on the meter when performing the following steps.
1. Direct-meter mounting requires a 100W-R endpoint for the Badger ADE register or a 100WP-R for the
RTR register. Both endpoints have three wires:
(1)
brown insulated wire
(2)
yellow insulated wire
(3)
gray insulated wire
Note For an RTR register, tuck the unused yellow wire into the housing.