User's Manual
Installing the 100W Endpoint
TDC-0909-002 100W and 100WP Pit Datalogging Water Endpoint Installation Guide 24
Proprietary and Confidential
Optional Leak Sensor Installation
Leak Sensors (LS) analyze water flow sound patterns to detect new, evolving, and pre-existing leaks. LS
analysis data is uploaded to mlogonline⢠Network Leak Monitoring for data analysis and accessed through a
secure Internet portal unique to your utility. This section describes installation of the Leak Sensor (LS) in a
100W system.
The 100W endpoint stores 20 days of Leak Sensor data. On the 21st day, the 100W begins to write over stored
data in a first in, first out manner.
The 100W automatically detects the presence of connected Leak Sensors. The 100W will automatically detect
the Leak Sensor within 22.5 minutes and begin reading Leak Sensor data. To immediately detect the Leak
Sensor and begin reading data, perform a Check ERT with a handheld computer running FDM software.
The LS is used in conjunction with both indoor (basement) and outdoor (mounting on the exterior of the
house) 100W endpoint installations. LS devices are mounted on a water service pipe or meter insetter (meter
horn) and connect to the appropriate endpoint wires as described in To connect the Leak Sensor to the 100W
endpoint on page 25. The mounting bracket shipped with the Leak Sensor accommodates an (up to) 1-1/2-
inch OD pipe. An optional mounting bracket is available for pipe sizes (up to 2 1/2-inch OD).
Required Equipment
Equipment
Itron Part Number
Description
Leak Detection Sensor
LDS-0001-002
LDS with inline connector, environmental connector cap; 5-foot
cable, and mounting bolt (fits up to 1 1/2-inch OD pipe).
Optional mounting bracket
CFG-0349-002
Mounting bolt fits up to 2 1/2-inch OD pipe.
100W endpoint
ERW-1300-002
Dual port 100W for LS and environmental connector caps.
25-foot extension cable
CFG-0349-101
25-foot cable with coordinating connectors (LS blue connector,
register black connector).
100W LS environmental replacement
cap
MSC-0019-005
Protects Leak Sensor connector when the Leak Sensor is not
connected to the 100W endpoint.
Warning When the 100W or 100WP is installed but the Leak Sensor is not attached, you
must protect the blue Leak Sensor port with the environmental cap (MSC-0019-005). If you
remove the Leak Sensor from the 100W, the environmental cap must be replaced to protect
the connector.