User's Manual

Using an Inline Connector
TDC-0909-002 100W and 100WP Pit Datalogging Water Endpoint Installation Guide 36
Proprietary and Confidential
3. Twist the register cable's black coupling nut to align the two tabs.
4. Install the security seal as shown. Push it until it snaps into place.
Note For future meter or endpoint servicing, break the security seal by pulling the seal apart. The original
protective connector covers can be reused if kept clean and dry. Install a new security seal after servicing
either device. To order more parts, see the Water Endpoint Ordering Guide (PUB-0063-001).
Caution Shield connectors with protective environmental covers. Do not leave an exposed connector in
the field.
Leak Sensor connector environmental cover: MSC-0019-005
Register connector environmental cover: MSC-0019-001, 1-year life.
The Leak Sensor environmental cap employs multiple seals to increase cap life. The Leak Sensor's cap
design allows utilities to install the endpoint and install the Leak Sensor at a future date.