User's Manual

TDC-0909-000 100W Datalogging Endpoint Installation Guide 33
Proprietary and Confidential
This section describes the connections of the 100W to the water meter register using the
inline connector assembly. Follow the manufacturer's recommended procedure for installing
the water meter register on the meter.
To connect the inline connector
Note If an inline connector is not used and the 100W is already connected to
the water meter register, skip this step.
1. Remove the protective cover from the connector by twisting the two halves in opposite
directions. Pull the halves apart.
Caution Verify the connector halves are clean and dry before assembly.
If any of the following conditions occur, do not install the endpoint:
Any of the three pins are damaged or missing.
The O-ring is missing.
The cable is cut or nicked
2. Connect the register cable to the endpoint connector. Holding the connectors by the
back shells, rotate one end to align the keyed slots. Push until snug. Slide the black
coupling nut over the O-ring. Make sure the O-ring stays seated. If the O-ring does not
stay seated, disconnect and try again.
A P P E N D I X A
Using an Inline Connector