User's Manual

Chapter 5 Optional Remote Antenna Installation
30 TDC-0909-000 100W Datalogging Endpoint Installation Guide
Proprietary and Confidential
2. From the bottom side of the lid, screw on the threaded collar two or three turns. Turn
the threaded collar until it is tight against bottom of the pit lid. Verify the antenna
dome does not move up and down or shift laterally .
Note Ensure the beveled edge (1) of the threaded collar is toward the top of the lid
(2). The Itron-recommended placement centers the remote antenna and takes up the
extra space in mounting holes up to 2 1/2-inches.
To connect the remote antenna coupler to the 100W
1. Insert the remote antenna cable coupler into the 100W s antenna slot with the flat side
of the coupler against the 100W housing.
2. Push the antenna coupler into the antenna slot until the coupler locks into the tabs of
the antenna slot.