User's Manual

Pipe Preparation
TDC-0909-000 100W Datalogging Endpoint Installation Guide 27
Proprietary and Confidential
4. Verify the pipe’s mounting surface is free from dirt and debris. Place the curved
surface of the LS against the pipe.
Caution Do not mount the Leak Sensor on a pipe coupler, joint, or nut.
5. Insert the U-bolt around the pipe and into the holes in the plate/Leak Sensor assembly.
Secure the U-bolt with the wing nuts. Tighten the wing nuts until snug (to a minimum
of 5-inch pounds) to prevent device rotation on the pipe. After the second wing nut is
tightened, check the Leak Sensor to verify the device is snug. If the sensor moves,
tighten the wing nuts until there is no movement.
Caution Do not tighten the Leak Sensor to more than 20 inch-pounds. Over-
tightening could damage the Leak Sensor housing and/or the pipe.