To install the Leak Sensor on a pipe (up to 2 1/2-inch OD)
1. Select a Leak Sensor mounting location within 5 feet of the 100W endpoint.
Note Leak Sensor mounting orientation is not critical. Orient the Sensor to best
accommodate your installation. The most important installation practice is to fasten
the Sensor securely to the pipe.
Caution The Leak Sensor must be mounted on the water input side of the meter.
Failure to follow this mounting requirement could result in errors in the leak detection
data. Installation requires Itron mounting hardware. Repair costs and service charges
relating to the use on non-compliant mounting hardware will be charged to the
customer. Contract Itron Support for more information.
2. Insert the mounting plate screws into the holes on the Leak Sensor's curved surface.
3. Secure the mounting plate to the Leak Sensor.