Optional Leak Sensor Installation
TDC-0909-000 100W Datalogging Endpoint Installation Guide 21
Proprietary and Confidential
To connect the Leak Sensor to the 100W
Caution Verify you have the correct 100W endpoint. Leak Sensors must
mount to Port B (top port) of the 100W. Connecting the LS to Port A (bottom port)
will cause electrical damage to the LS and 100W endpoint.
1. Remove the environmental cap from the 100W endpoint blue connector (B).
B. 100W blue connector: Leak Sensor connection
A. 100W black connector: Register connection
2. Remove the environmental cap from the Leak Sensor connector. Verify the connectors
(100W LS connector and the Leak Sensor connector) are clean and dry.
3. Align the Leak Sensor connector with the endpoint's blue connector and insert.