Chapter 4 Installing the 100W Datalogging Endpoint
14 TDC-0909-000 100W Datalogging Endpoint Installation Guide
Proprietary and Confidential
Wall Mount Installation
Select a flat vertical mounting surface. Install the endpoint in an upright position; locate the
endpoint as high as possible. To mount the endpoint to the wall in a water pit box, select a
mounting location on the inside of the pit box and try to maintain a distance of one to two
inches from the bottom of the pit box lid.
Caution Observe the following guidelines for mounting the 100W using the
wall mount procedure:
Endpoint positioning other than upright could negatively affect
radio performance and battery life.
Do not use gel connectors in pit environments.
Use only Itron-approved splice kits or inline connectors.
The 100W is suitable for use with up to 300 feet of Itron approved cable.
Required Tools and Hardware
Itron 100W Shelf Mount Kit
To install the 100W endpoint using the wall mount procedure
1. Select a vertical surface in the pit box or on a wall (for example, endpoints mounted in
basements).
2. Position the endpoint vertically so the top of the endpoint is between one and two
inches below the bottom of the lid.
3. Mark the location of the top mounting hole.
4. Drill a pilot hole in the pit box wall. Follow the screw manufacturer's recommendation
for the size of the pilot hole.