User's Manual

Rod Mount Installation
TDC-0909-000 100W Datalogging Endpoint Installation Guide 13
Proprietary and Confidential
6. The top of the rod should be three and one-half inches below the bottom of the lid.
Place the endpoint on the rod. Completely insert the rod into the endpoint's rod mount
hole. Do not force the endpoint onto the rod. If the endpoint does not slide freely on
the rod, remove the endpoint and examine the endpoint rod hole and rod for burrs or
obstructions. You may secure the endpoint to the rod with a self-drilling screw
through the hole in the top of the 100W rod mount cavity. The screw mounting hole is
shown in the following product image.
7. Installation is complete when the endpoint is perpendicular to the underside of the lid.
The endpoint must not contact the pit structure or lid.
Caution Verify the pit lid does not come in contact with the endpoint when the lid is
replaced. There must be a 1 to 2 inch space between the top of the endpoint and the
bottom of the pit lid. If the 100W is installed too high, too low, or is touching any of
the surrounding surfaces, adjust as necessary.