User's Manual

Chapter 3 Initializing and Connecting the 100W Datalogging Endpoint
6 TDC-0909-000 100W Datalogging Endpoint Installation Guide
Proprietary and Confidential
To connect the 100W to the register
Connect the 100W wires to the register screw terminals according to the following
table.
Register Manufacturer
100W wire color
Red
(data)
Black
(power/clock)
White
(ground)
Register screw terminal
Elster AMCO Invision
R
G
B
Elster AMCO Scancoder
R
G
B
Elster AMCO evoQ4 (Q4000)
R
W
B
Hersey Translator
G
R
B
Badger ADE
G
R
B
Sensus ECR
G
R
B
Sensus ICE
G
R
B
Metron Farnier
G
R
B
Itron (Actaris) Coder
G
R
B
ProRead
R
B
G
ARB V
R
B
G
Performance ETR
G
R
B
Severn Trent SM700
SmartMeter
(Sensus Protocol)
G
R
B
Caution Wire should wrap one complete revolution around register screw.
Completely tighten register screws and verify wire insulation is not under screw
terminal heads or intermittent electrical connection may occur. You must use a
moisture-proof sealant if the meter is used outdoors or in any environment where
moisture can collect on the screw terminals.
Using an Extension Cable
Order the 25-foot inline connector extension cable assembly (CFG-0151-401) to extend the
100W with the inline connector.