Connecting and Configuring the Module and Instrument
TDC
-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 23
Proprietary and Confidential
4. Connect the 100T-HON telemetry module to the instrument RS232 terminal block connections on the
CMOS to RS232 adapter board. Connect Rx, Tx, and COM (Gnd).
Note The Mini-Max may have the RS232 adapter board connected to the external RS232 case connector.
The external case connector must be replaced with the connector capable of using an external shorting
plug and the RS232 connection. The 100T-HON telemetry module wires are gel connected to the internal
wires and the external shorting plug is installed.
5. (Optional) To connect the 100T-HON telemetry module for mechanical uncorrected volume pulser data,
connect the 100T-HON telemetry module to the three-wire screw terminal connector on the mechanical
pulser board. Connect only to the NO and COM.