This section provides the instructions to install the 100T-HON telemetry module on Honeywell Instruments:
• Mini-AT
• Mini-Max
• ERX
Mini-AT Mini-Max ERX
Installation Overview
Installing the 100T-HON telemetry module to a Honeywell Mercury instrument involves five tasks:
1. Programming the instrument (for more information, see Programming the Mercury Instrument Parameters
on page 15 or reference the Mercury Instrument Programming Guide for more information).
2. Installing Mercury retrofit parts (if required).
3. Attaching the 100T-HON telemetry module to a pipe or vertical flat surface (wall) (for more information,
see Mounting the 100T-HON Telemetry Module on page 8).
4. Connecting the 100T-HON telemetry module to the Mercury Instrument Volume Corrector (see To wire
the 100T-HON telemetry module to the Mercury Instrument).
5. Programming the 100T-HON telemetry module (see Programming the 100T-HON Telemetry Module).
Programming the Mercury Instrument Parameters
The Honeywell Mercury Instrument configuration must support the connection of the 100T-HON telemetry
module. Complete instrument configuration using a separate application (not using the Itron network,
applications, or 100T-HON).
C HAPTER 3
Connecting and Configuring the Module and Instrument