Mounting the 100T-HON Telemetry Module
TDC
-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 13
Proprietary and Confidential
To mount the 100T-HON telemetry module on a wall or other flat vertical surface
1. Using one of the three 1-1/2-inch mounting screws from the module installation kit, turn the mounting
screw for the mounting lug (top of the module) part way into the mounting surface.
2. Place the 100T-HON telemetry module mounting lug recess (on the top of the module's backplate) just
under the screw head.
3. Slide the module upward until the screw head fits completely inside the mounting lug recess. Several
adjustments may be necessary to properly position the screw for module mounting.
4. Install the bottom two mounting screws. Fasten the screws in an alternating pattern until fully tightened to
secure the module firmly in position.
To install tamper seals and cable ties
1. Place the new tamper seals from the module installation kit over the 100T-HON telemetry module
mounting screws.