User's Manual

Mounting the 100T-HON Telemetry Module
TDC
-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 10
Proprietary and Confidential
To mount the pipe bracket on a vertical pipe
1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number
CFG-0005-003).
2. Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band through the holes in the pipe bracket. The pipe bracket must be oriented
as shown below.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. Push the end of the
band through the band clamp screw assembly. Turn the band clamp's screw assembly to fit into the pipe
bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe.
Caution The pipe bracket must fit firmly against the pipe to prevent slippage.
To mount the adapter plate on the pipe bracket
Caution Vertical mounting position is important to maximize RF performance. Mount the 100T-HON
telemetry module with the module label arrow pointing up. The module's arrow must never point to either
side or upside down. The module tilt tamper functionality is designed to operate with the module installed
vertically.