-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 8
Proprietary and Confidential
This chapter provides the instructions to mount the 100T-HON telemetry module on a pipe or other flat
vertical surface (wall).
Installation Options
Mount the 100T-HON telemetry module using the Pipe Mount or Wall Mount (Flat Surface) procedure.
• Pipe Mount. Pipe mounting is used in conjunction with the Remote Mount Kit (Itron part number CFG-
0005-003). The pipe mount option places the module on a pipe near the meter or instrument (not on a wall
surface). This option requires a meter manufacturer's cable to connect the module to the meter or
instrument.
• Flat Vertical (Wall) Mount. Installation using the wall mount option places the module on a wall or
other vertical surface. A cable connects the module to the meter or instrument.
Mounting Screw Specifications
Application Itron Part
Number
Description
To mount adapter plates on
pipe brackets
575-9930-016
8-16 x 1/2-inch length, type 8 slotted pan-head
tapping screw, corrosion-resistant steel
To mount the module on
adapter plates
575-9930-032
8-16 x 1-inch type 8, slotted pan-head tapping screw,
corrosion-resistant steel
To mount the module on sheet
metal surfaces (to mount
modules to wood surfaces, a
comparable wood screw is
required)
SCR-0009-001
10-16 x 1 1/2-inch type AB thread for sheet metal,
Phillips pan-head tapping screw, corrosion-resistant
steel
C HAPTER 2
Mounting the 100T
-HON Telemetry Module