Mounting the 100T-CP Module on the Test Station Post
TDC
-1344-000 100T-CP Cathodic Protection Telemetry Module Installation Guide 5
Proprietary and Confidential
Mounting the 100T-CP Module on the Test Station Pipe
The following items are required to mount the 100T-CP on the test station pipe:
Itron Part
Number
Description
TEL-1000-003 100T-CP cathodic protection telemetry module
CFG-5006-701 100T-CP Hardware Installation Kit
Kit includes:
(1) one band clamp
(2) two tamper seals
pipe bracket
adapter plate
lightning suppressor kit (also includes 2 gel-
connectors)
Screws:
(2) 1/2-inch, to attach the adapter plate to pipe bracket
(2) 1-inch, to attach the telemetry module to the
adapter plate
(3) 1 1/2-inch, to attach the telemetry module to a
vertical surface (wall)
CFG-5006-710
(may be ordered
with 100T-CP
Harware Kit or
separately)
Lightning Suppressor Kit
Kit includes:
Lightning suppressor
(2) gel connectors
To mount the pipe bracket on a vertical pipe
Warning A vertical mounting position is important to maximize RF performance. Mount the 100T-CP
with the module's label arrow pointing up. The module's arrow must never point to either side or upside
down. The module's tilt tamper functionality is designed to operate with the module installed vertically.
1. Drill a 3/16" hole for the 100T-CP cable in the riser post 1-1/2" below the test station base.
Caution Protect wires within riser post from damage when the hole is drilled.