User's Manual

Code Settings
Screw Specifications
For mounting adapter plates on
pipe brackets
For mounting ERTs on adapter
plates
For mounting ERTs on wood or
sheet metal surfaces
8–15 x 1/2 Type A slotted pan
head tapping screw,corrosion
resistant steel
8–15 x 1 Type A slotted panhead
tapping screw, corrosion resistant
steel
10–16 x 1 1/2 Type AB Phillips
panhead tapping screw, corrosion
resistant steel
Code Settings
Item Code Settings and Corresponding Terminal Board Channel Terminal Board Connections*
Instrument
Type
Form A Channel A Channel B Channel C
Ka, Ya = Channel A Kb, Yb =
Channel B Kc, Yc = Channel C
#056 #093 #057 #094 #058 #095 #096 #115
0 n/a n/a n/a n/a n/a n/a n/a n/a
ERT does not support a Form-C
Pulse Output Board
3 2.0000 0 2.0000 0 2.0000 0 1, 2, 3 or 4 1 or 2
Ka, Kb, Kc (Red Wire) Ya, Yb, Yc
(Blue & White Wire). Connection
must be on same terminal board
channel (i.e., Ka/Ya; Kb/Yb;
Kc/Yc).
ECAT:
1
n/a n/a n/a n/a 2.0000 0 1, 2, 3 or 4 1 or 2
Kc (Red Wire) Yc (Blue & White
Wire) For this option, ERT must be
connected to Channel C.
Mini with
Form A
Mainboard:
1
2.0000 0 n/a n/a n/a n/a 1, 2, 3 or 4 1 or 2
K (Red Wire) Y (Blue & White
Wire) Jumper settings must be on
J1-B as stated in the Mercury Quick
Reference Guide (page 45) for
Form-A.
2 2.0000 0 2.0000 0 n/a n/a 1, 2, 3 or 4 1 or 2
K (Red Wire) Y (Blue & White
Wire) Jumper settings must be on
J1-B as stated in the Mercury Quick
Reference Guide (page 45) for
Form-A.
Mini-AT:
0
n/a n/a n/a n/a n/a n/a n/a n/a
ERT does not support a Form-C
Pulse Output Board
Mini-Max: 2 2.0000 0 2.0000 0 n/a n/a 1, 2, 3 or 4 1 or 2
K (Red Wire) Ya OR Yb (Blue &
White Wire)
* For more information, see pages 11-20 of the "Basic Pulse Information for Mercury Instruments, Inc., Electronic Volume Correctors" manual, or
contact Mercury Instruments at 513-272-1111.
Natural Gas Solutions 100G Installation Guide for Mercury Electronic Volume Correctors 3
DRAFT