User's Manual
Table Of Contents
Physical Specifications
• Item # 093: Type of gas volume information to be sent. For CorVol selected, must be
set at 0.
• Item # 094: Type of gas volume information to be sent. For CorVol selected, must be
set at 0.
• Item # 095: Type of gas volume information to be sent. For CorVol selected, must be
set at 0
• Item # 096: Corrected Volume Display: Must be set at 1, 2, 3 or 4 blanks. ERT does
not support a setting of 0 blanks.
• Item # 115: Output Pulse Code: Must be set at 1 or 2.
Operating temperatures: –40°F to + 158°F (–40°C to +70°C)
Operating humidity: 5 to 95 percent non-condensing relative humidity
Product identification: Numeric and bar-coded ERT module type and serial number
FCC compliance: Part 15 certified
Intrinsically safe per: Factory Mutual and UL Class 1, Division 1, Groups C and D
Physical Specifications
Materials of construction: Black polycarbonate housing; encapsulated electronics
Operational Specifications
Receive frequency: 952 and 956 MHz (MAS Bands)
Transmit frequency: 910 to 920 MHz
Data integrity: Verified in every data message
Natural Gas Solutions 100G Installation Guide for Mercury Electronic Volume Correctors 31
DRAFT