User's Manual
Table Of Contents
Pipe Mounting
4. Install the two ERT module mounting screws you got from the installation kit.
When the ERT module is properly mounted on the adapter plate, it should look like
this.
5. Tighten the screws to 9 to 12 inch-pounds of torque.
Program the ERT
The ERT must be programmed using the FC200SR with EndPoint-Link software. See the
Endpoint-Link ERT Programming Guide (TDC-0411) for more information.
IMPORTANT You must perform the following programming procedure for
the ERT module to function properly.
When programming the ERT module, you must take note of the drive rate shown on the
index of the meter. Program the meter based on the drive rate shown on the index.
Natural Gas Solutions 100G Installation Guide for Mercury Electronic Volume Correctors 15
DRAFT