Specifications
Functional Specifications Description
Power Source
100G Datalogging
Two "A" cell lithium batteries
Tamper Detection Tilt tamper and magnetic tamper
FCC Compliance Part 15 certified
Industry Canada Compliance RSS-210 certified
Intrinsically Safe per UL Class I, Division 1, Groups C and D
Product Identification Numeric and bar-coded endpoint type and serial number
Construction Materials
Gray polycarbonate housing and back plate with encapsulated
electronics
Operational Specifications Description
Operating Temperatures -40° to 158° F (-40° to +70° C)
Operating Humidity 5 to 95 percent relative humidity
Program Frequency 908 MHz
Transmit Frequency Spread spectrum 908 to 924 MHz ISM band
Data Integrity Verified in every data message
Related Documents
Document Title Document Part Number
Gas Endpoint Meter Compatibility List PUB-0117-002
Gas Endpoint Ordering Guide PUB-0117-001
100G Datalogging Specification Sheet Publication 100941SP-01
Endpoint Link® Programming Guide TDC-0744
Meter Compatibility List
100G Datalogging Endpoint – Remote Disconnect Meter Compatibility
Mfg. Model Description Class Comments Endpoint
Type
Endpoint
Part No.
Itron/Actaris/
Schlumberger/
Sprague
METRIS 250 Remote disconnect Residential
100G Datalogging ERG-5002-105