Attaching the 100G Datalogging Remote Disconnect Gas Endpoint Assembly to the Mete
r
100G Datalogging
Installation Guide – Remote Disconnect
TDC-0844-000 17
2. Align the endpoint wriggler (1) so one of its four drive slots lines up with the meter's
drive dog (2).
Warning Failure to correctly align the meter drive post (2) and endpoint
wriggler drive slots (1) can cause binding and lead to poor registration or meter
failure. You must properly align the meter drive dog with the endpoint wriggler
drive fin.
3. Carefully place the endpoint on the meter.
4. Install endpoint to meter mounting screws in an alternating fashion. Use the original
mounting screws if they were the correct size and not corroded. If the original screws
were discarded, use the correct replacement screws (see Installation Prerequisites on
page 8.)
• Insert the right index cover mounting screw and tighten the screw enough to hold it
in place. Do not completely tighten.
• Install the left index cover mounting screw and tighten to a snug fit.
• Finish by tightening the right mounting screw to a snug fit. Tighten each mounting
screw evenly.
Important Meter manufacturers: torque the mounting screws 15 to 20 inch-
p
ounds.