User's Manual
Table Of Contents
- Document Conventions
- 100G Datalogging Remote Disconnect Gas Endpoint
- Itron METRIS 250 Meter Installation
- To remove the index from the meter
- To assemble the 100G Datalogging Remote Disconnect Gas endpoint and index
- To program the 100G Datalogging Remote Disconnect Gas endpoint
- To attach the 100G Datalogging Gas Endpoint to the meter
Installation Prerequisites
100G Datalogging
Installation Guide – Remote Disconnect
TDC-0844-000 13
2. Screw the 10 - 24 x 1/4" screws into the index mounting posts two turns. Do not
tighten the screws.
3. Align the index wriggler (1) with the endpoint drive post (2). Carefully slide the index
onto the mounting screws. Verify the 100G Datalogging Gas Endpoint's housing drive
post makes positive engagement with the index wriggler. Hold the index in place and
tighten the index mounting screws.
Caution Indexes have varying drive mechanism styles. Failure to align the
endpoint wriggler with the index drive post can cause binding and lead to poor
registration or meter failure. To verify proper engagement of the index to the
endpoint housing, spin the wriggler one clockwise rotation, then one-
counterclockwise rotation. Do not spin more than one complete rotation. The
wriggler should spin freely, with little or no resistance.
4. Slide the endpoint cover over the index and housing. Verify the cover is installed
correctly. The endpoint label should be clearly visible and easily read.