User's Manual

Electronic Instrument Installation
Connections to the three output pulse channels are completed using loose unterminated wires (the individual
wires from a cable) and gel-connectors. The TCI unit has six unterminated wires and six gel-connectors (Itron
part number CON-0023-001) to enable pulse connections to ancillary devices. Loose wires are located inside
the gray adapter plate behind the black strain relief fitting.
Adapter plate with Loose cable wires Honeywell TCI adapter backplate
black fitting (Honeywell part number 22-1929)
To make TCI pulse connections
Note Connect one ERT module/channel to the alarm output if the modules are used on channels A and B.
1. Remove strain relief fitting by unscrewing from the gray adapter plate.
Note Do not remove the fitting's hex nut. Unscrew the entire fitting from the gray adapter plate. A tether
line is secured to the strain relief fitting. When the strain relief fitting is removed, the tether line pulls the
unterminated wires out of the adapter plate for access to the loose wires.
2. Loosen the strain relief fitting hex nut and remove the white plug from the center.
3. Place the strain relief fitting onto the field pulse cable.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 48