5. Remove the excess cable tie using a hand-held side-cutter pliers. The cable tie performs as a cable strain
relief to mitigate the risk of destructive tension on the lead wires.
6. Tuck the three gel connectors and cable tie inside the module housing, as shown in the following
placement schematic illustration.
7. Install the remote ERT module backplate using the four screws previously removed from the module and
a Torx T-10 screwdriver.
Important Verify the cable tie and gel connectors are inside the module housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9 to 12 inch-pounds.
8. Install the module on the wall or a pipe using the Pipe Installation Kit (Itron part number CFG-0005-003)
or install the module on the Romet AdEM meter using the Romet ERT mounting bracket (Romet part
number 46-444-2).
Programming the Remote ERT Module
Caution You must program the 100G series remote gas module before use.
Program the 100G, 100G DL, 100G DLN, and 100G DLT ERT modules using:
• An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or
• A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher or
• A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 74