User's Manual
Electronic Instrument Installation
Required Materials
The following materials are required for ERT module installation with the Romet AdEM series correctors
using a Cannon connector:
Description
Part number
Connection options
Cannon cable (part number: 43-035-40*)
Pigtail Option**
Romet AdEM communication cable *
RometLink communication software *
3 gel cap connectors CON-0023-001
3M crimping tool
Torx T-10 screwdriver
Remote ERT module with backplate and four
included Torx screws (included with module)
ERG-5007-503
* Must be purchased from Romet.
**Pigtail option must be selected when the AdEM is ordered from Romet.
Meter Preparation
Meter set up requires confirmation of communication settings with the AdEM corrector. Communication
confirmation requires the RometLink software and the Romet communication cable.
To configure the AdEM corrector settings
1. Install the RometLink software on your PC.
2. Connect the AdEM corrector communication cable to your computer and the AdEM corrector.
3. Add the AdEM meter to your Phone Book.
a. Open the RometLink software and log on.
b. From the Talk to Unit tab, select Check > All.
A dialog box opens asking if you want to add the unit in the Phone Book.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 70