User's Manual
Electronic Instrument Installation
20. Enter the following parameters in the Corrected Pulse Output Setup section in the lower left of the
window.
• Primary Pulse Output. Select K1.
• Optional Pulse Output. Set to "Disable".
• Pulse Out On ms 70mS
• Pulse Out Off ms 500mS AMR
• Current/Test/Pulses to Output. Select the number of pulse output pulses to send as a connection test
for the remote ERT module.
• Out Cubic Unit/Pulse. Enter the same setting as the ERT module. For example, if the ERT
module consumption is in MCU (thousand cubic feet), set Out Cubic
Unit/Pulse to 1000.
21. Click Send All Changes.
22. Verify all parameters are completed and correct.
23. Click Disconnect.
100G Series Remote Module Installation to the Romet AdEM Using a
Cannon or PG9 Factory-Installed Pigtail Cable
Romet™ AdEM
®
-S/-T/-PTZ 100G Series Remote using the Romet™ Meter Mounting Bracket
This section describes remote 100G ERT module installation with the Romet AdEM
®
-S, AdEM
®
-T and
AdEM
®
-PTZ series correctors.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 69
Proprietary and Confidential