User's Manual
Electronic Instrument Installation
14. Enter the following parameters in the Uncorrected Pulse Output Setup section in the lower right of the
window.
• (Set to ERT 2 connection) Enable POut 5 (17, 18)
• Current/Test Pulses to Output 0.0000
• Out Cubic Unit/Pulse (set to 10 or more dependent on application) 10.00
Important If your software does not have an option to use POut 5 for the Uncorrected Pulse Output,
contact Eagle Research to obtain the correct software version. You must uninstall the previous Field
Manager version, delete (or rename) the Field Manager folder (C:/Field Manager--copy important files
before you delete the folder), and then install the new or updated version.
15. Enter the following parameters in the Corrected Pulse Output Setup section in the lower left of the
window.
• Primary Pulse Output (set to the ERT 1 connection) Enable POut 4 (15, 16)
• Optional Pulse Output Disable
• Pulse Out On ms 70mS
• Pulse Out Off ms 500mS AMR
• Current/Test/Pulses to Output 0.0000
• Out Cubic Unit/Pulse (set to 10 or more dependent on application) 10.00
16. Click Send All Changes.
17. Verify all parameters are correct.
18. Click Disconnect.
To change the MPplus 60291 database and Itron ERT module settings using Eagle Research
Field Manager
Important This information is subject to change without notice. Refer to the Eagle Research product
documentation to verify the most current information about programming and configuring the corrector
for use with the 100G series remote ERT module.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 66