User's Manual
Electronic Instrument Installation
4. Twist the blue and white wires together and connect them to the Honeywell Instrument terminal strip
connector (Phoenix connector) following the Honeywell Instrument Item Code Settings on page 43 Table.
5. Connect the red wire following the Item Code Settings on page 43 Table.
Note In Honeywell Instrument EC-AT correctors, the connector may be soldered to the pulse board.
6. See Mounting the 100G series remote gas module on page 9 for module mounting instructions.
Wiring Dual ERT Modules to a Honeywell Instrument
This section includes the information to wire dual ERT modules to a single Honeywell Instrument. Installation
requires the correct programming parameters (see Item Code Settings on page 43).
With Itron 100G series remote gas modules, utilities can receive corrected and uncorrected consumption
values by installing two ERT modules. The ERT module for corrected reads is attached to the corrector's
pulse output. The ERT module for uncorrected reads is attached to the input switch board. The corrected
pulse output is programmable; the uncorrected pulse output is dependent on the connected meter's drive rate.
Important Some Honeywell Instruments have two pulse outputs so the uncorrected pulse output
could be connected to the additional output, but the connection should be to the input switch board in
case the corrector battery fails. Counts will be collected if the uncorrected pulse is connected to the
switch board since the board is not dependent on battery power.
Dual remote ERT modules mounted on a Honeywell Instrument
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 45