User's Manual
Electronic Instrument Installation
6. Connect the red remote ERT module wire to terminal 18 on the MPplus terminal block.
For corrected leads:
7. With the MPplus door open, insert the flying leads from the remote ERT module into the compression
connector on the right of the MPplus housing.
8. Pull the lead wires through the compression connector until there is adequate wire to reach the terminal
block labeled 15, 16, 17, 18, 19, 20, 21, and 22.
9. Tighten the compression connector.
10. Twist the remote ERT module's blue and white wires together.
11. Connect the twisted blue and white wires to terminal 15 on the MPplus terminal block.
12. Connect the red remote ERT module wire to terminal 16 on the MPplus terminal block.
13. Close and latch the MPplus corrector door.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 60
Proprietary and Confidential