User's Manual
Electronic Instrument Installation
Eagle Research Meter Installation
MPplus XARTU-1
This section describes remote 100G ERT module installation with the following Eagle Research Meter
volume correctors.
• MPplus
• XARTU-1
Configuration with the meter is dependent on your system's application. See the Eagle Research meter product
documentation for Eagle Research Field Manager database configuration information.
These installation instructions provide the information to install two 100G modules--one for corrected reads
and one for uncorrected reads. The installation procedure is the same for one ERT module (uncorrected or
corrected); the hardware is similar between the uncorrected and corrected outputs.
Eagle Research meter outputs are optically isolated from the meter's control board and each other. The volume
corrector's software configuration controls the port's operation. Follow the documentation and these
installation instructions to ensure correct installation and compatibility.
Required Materials
The following materials are required for ERT module installation with the Eagle Research volume corrector.
Description
Part number
Eagle Research mounting rail Eagle Research part number 1010247
Remote 100G ERT modules ERG-500X-502
Customer-supplied Phillips-head screwdriver
To mount the remote 100G ERT module and the Eagle Research volume corrector
Note These instructions show the Eagle Research MPplus volume corrector. Installation is the same for
the XARTU-1 corrector.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 58
Proprietary and Confidential