User's Manual

Electronic Instrument Installation
2. For the cable gland or conduit fitting:
a. Route the cable from the 100G series remote gas module through the IMC\W2 cable gland/conduit
connector.
To receive uncorrected reads: connect the red wire to the terminal block 3 (TB3 telemetry output)
GND1 (ground) position (B). Connect the white and blue wires to the pulse output 1 position (A).
To receive corrected reads: connect the red wire to the GND 2/3 (ground) TB3 telemetry output position
(C). Connect the white and blue wires to the pulse output 2 position.
b. Tighten the cable gland fitting around the cable. Apply 15 inch-pounds torque.
Note ERT modules using the flying lead cable assembly (GE Dresser part number 055018-700) are
factory wired to terminal block 3 (TB3) according to IMC\W2 pulse output default configuration. Consult
the customer specification for other wiring configurations.
To test the 100G Series Gas ERT Module IMC\W2 installation
1. Connect the IMC\W2 to the PC using the serial cable.
2. Using the GE Dresser User Terminal (UT) communications software, connect to the IMC\W2.
3. Read the uncorrected or corrected count number on the 100G series remote gas module with the Itron
endpoint reading device. Compare the IMC\W2 uncorrected or corrected amounts to the 100G series
remote gas module.
4. Input approximately 20 pulses to the 100G series remote gas module. Verify the uncorrected or corrected
counts on the IMC\W2 and the 100G series remote gas module are the same.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount 56
Proprietary and Confidential